Basement apartment fire separation in Georgetown

The ceiling over the suite is a safety system, not a finish.

The units must be separated so fire and smoke are held back long enough for people to get out. The rating depends on the age of the house and how the alarms are set up. It is the hidden core of basement apartment construction, and it has to be inspected before it is covered up.

Call (416) 820-3775 Send the details

Which rating applies?

From the Town's guide, for a house with one additional unit:

  • New or under five years old: 45 minutes, or a continuous smoke-tight barrier of Type X gypsum board.
  • Five years or older: 30 minutes is acceptable.
  • Five years or older with interconnected smoke alarms: a 15 minute horizontal separation is acceptable.
  • Sprinklered houses may have the rating waived.

A house with two additional units has stricter rules and needs a professional designer.

What about doors and openings?

Doors in a separation are rated for 20 minutes and need latches. Existing solid core doors at least 45 millimetres thick, or metal clad doors, may be accepted in older houses. Pot lights, plumbing penetrations and duct openings all need to be dealt with rather than just boarded around.

Is fire separation the same as soundproofing?

No. New walls and ceilings between units in an existing house also need a sound transmission rating of 43 or an accepted equivalent. Resilient channel and insulation in the joist space are common ways to get quieter floors.

What happens with a finished ceiling?

If the drywall is already up, you have to be able to show what it is and what is behind it. Where that cannot be shown, it is opened or covered with a new rated layer, which also costs ceiling height.

Common questions

Is ordinary drywall enough?

It depends on the rating and the assembly. Use the assembly shown on the permit drawings, not a guess from the shelf.

Does the furnace room need separating?

Usually it is treated as shared or service space and separated from the units. The drawings show how.

Can I add pot lights afterwards?

Cutting holes in a rated ceiling can undo it. Plan lighting before the board goes up.

Related pages

Separate Entrance

The door is where privacy, safety and the foundation all meet.

Egress Windows

A bedroom window is only an exit if a person can get through it.

Heating, Air & Alarms

One furnace and two households needs a plan.

Check your basement before you build

(416) 820-3775

Have these ready:

  • Age and type of house
  • Ceiling height, including under ducts
  • Any door from the basement to outside
  • How many cars the driveway holds

Tell us about the basement

Used to answer your enquiry. Privacy.

Call (416) 820-3775