(416) 820-3775

Basement egress windows in Georgetown

A bedroom window is only an exit if a person can get through it.

Where a bedroom level has no door leading straight outside, the Town's guide calls for an egress window that opens from inside without tools, with at least 0.35 square metres of open area and no side under 380 millimetres. Existing windows may be accepted in some older houses with direct access outside. It is part of basement apartment construction.

Call (416) 820-3775 Send the details

How big is that in practice?

The 0.35 square metres is the open part, not the frame or the glass. A slider that opens halfway may fall short even though the window looks large. Check the clear opening on the product sheet before ordering.

What about the window well?

A window that opens into a well needs at least 550 millimetres of clear space in front of it. The well should also leave room to climb out when there is snow in it, and it needs to drain.

How high can the sill be?

Basement windows are exempt from the general maximum sill height, but the code commentary recommends no higher than 1.5 metres above the floor, with a built-in step or furniture where that cannot be done.

Does light matter too?

Yes, separately from escape. Living and dining rooms are listed at glass equal to 10 percent of the floor area and bedrooms at 5 percent, with a reduction of up to half allowed in existing buildings where it does not affect escape or ventilation. Larger openings may mean cutting the foundation.

Common questions

Can an existing window opening be enlarged?

Often. Cutting down a foundation wall needs a proper header, drainage and a place on the permit drawings.

Does every room need an egress window?

The rule is about escape from bedroom levels without a direct door outside. Your drawings should show which windows serve that purpose.

Can bars go on the window?

Anything that needs a tool or key to open defeats the purpose.

Related pages

Separate Entrance

The door is where privacy, safety and the foundation all meet.

Fire Separation

The ceiling over the suite is a safety system, not a finish.

Heating, Air & Alarms

One furnace and two households needs a plan.

Check your basement before you build

(416) 820-3775

Have these ready:

  • Age and type of house
  • Ceiling height, including under ducts
  • Any door from the basement to outside
  • How many cars the driveway holds

Tell us about the basement

Used to answer your enquiry. Privacy.

Call (416) 820-3775